电气材料明细
管理:EA-1310401
1.总电源序号区域电源类型总电流(A)引出配电盘编号引出电源开关型号末端配电盘编号末端电源开关型号HSM1-630S/630AHSM1-630S/630AHSM1-125S/100AHSM1-200S/160AHSM1-400S/400AHSM1-400S/400AHSM1-125S/100AHSM1-630S/630AHSM1-630S/630AHSM1-125S/100A电缆长度(米)截面积(mm)4*(YJV-3*150+1*70)1*(YJV-3*25+1*16)1变电室内3P/200V1360SB-10HSM8-2500A万能式断路器SB10-1152345678变电室内评价实验室振动试验室评价实验室评价实验室振动试验室3P/400V3P/400V3P/400V3P/200V3P/200V3P/200V500A315A400V受电盘母排HSM1-630S/500AHSM1-400S/400ADP-27DP27-01DP27-02SB-01SB-02SB-032011875118118752*(YJV-3*95+2*50)2*YJV3*70+2*35YJV-3*25+2*162*(YJV-3*150+1*70)2*(YJV-3*150+1*70)YJV-3*25+1*16DP-2798A681A6A58ASB10-1HSM1-125S/100AHSM1-630S/630AHSM1-630S/630AHSM1-125S/100A2.评价实验室200V设备序号设备名称电源类型引出配电盘编号引出配电盘总开关型号末端配电盘编号末端引出开关型号电缆备注长度(米)303050截面积(mm)YJV-3*35+1*16YJV-3*35+1*16YJV-3*35+1*16123恒温恒湿槽(中)恒温恒湿槽(大)ACAVR电源被试验机计测器电源被试验机计测器电源3P/200V3P/200V3P/200V3P/200V3P/200VSB-01HSM1-630S/630A3P/200V3P/200V3P/200V3P/200V3P/201V3P/200V3P/200V3P/200V3P/200V3P/200VSB-02HSM1-630S/630AB-01B-02B-03HSM1-160S/160AHSM1-160S/160AHSM1-250S/200AHSM1-125S/50AHSM1-125S/50A4被试验机计测器电源被试验机计测器电源被试验机计测器电源B-04HSM1-125S/50AHSM1-125S/50AHSM1-125S/50A45YJV-3*95+1*505671011DCAVR电源齿轮转矩试验机短路实验电源噪音实验电源大型负荷机小型负荷机中型负荷机B-05B-06B-07B-08B-09B-10B-11HSM1-125S/25AHSM1-125S/40AHSM1-125S/125AHSM1-250S/200AHSM1-250S/250AHSM1-125S/100AHSM1-250S/160A45203525304540YJV-3*4+1*2.5YJV-3*10+1*6YJV-3*25+1*16YJV-3*70+1*35YJV-3*95+1*50YJV-3*25+1*16YJV-3*35+1*163.评价实验室400V设备序号设备名称电源类型引出配电盘编号引出配电盘总开关型号末端配电盘编号末端引出开关型号电缆备注长度(米)截面积(mm)被试验机计测器电源被试验机计测器电源1被试验机计测器电源被试验机计测器电源被试验机计测器电源2短路实验电源3P/400V3P/400V3P/400VDP27-013P/400V3P/400V3P/400VB-13HSM1-400S/400AB-12HSM1-125S/50AHSM1-125S/50AHSM1-125S/50AHSM1-125S/50AHSM1-125S/50AHSM1-125S/80A35YJV-3*16+1*1045YJV-3*95+1*50